Labeling configuration entry
When you select the AsVorhS1, AsVorhQS1, AsVorhS2, AsVorhQS2 and GStk reinforcement variables, the longitudinal bars, cross bars and lattice girders are always calculated from the enclosing rectangle of the element! In the case of panels and/or recesses of irregular geometry, individual longitudinal bars, cross bars and lattice girders of the basic reinforcement may be excluded! This is ignored when the text is created!
Freely definable labels
For all precast wall types
PosNr |
[ - ] |
String |
Mark number |
ZusText |
[ - ] |
String |
Additional text for mark number |
FtID |
[ - ] |
Integer |
Precast ID |
Gew |
[to] |
Real |
Weight |
Vol |
[m3] |
Real |
Volume of element |
Lae |
[m] |
Real |
Length of element |
Hoe |
[m] |
Real |
Height of wall |
Dck |
[m] |
Real |
Thickness of wall |
ElemBez |
[ - ] |
String |
Type indicator for wall panel |
DickBez |
[ - ] |
String |
Thickness indicator for wall panel |
OberFlS1, OberFlS2 |
[ - ] |
String |
Surface name of visible leaf and invisible leaf of wall panels |
PA_ProjNr |
[ - ] |
String |
Project attribute: project number |
PA_AuftragNr |
[ - ] |
String |
Project attribute: contract number |
PA_Bauteil |
[ - ] |
String |
Project attribute: component |
PA_Geschoss |
[ - ] |
String |
Project attribute: story |
FtID |
[ - ] |
Integer |
Precast ID |
BetGue |
[ - ] |
String |
Concrete grade |
Gew |
[to] |
Real |
Total wall weight |
Lae, LaeS1, LaeS2 |
[m] |
Real |
Wall and/or leaf length |
Hoe, HoeS1, HoeS2 |
[m] |
Real |
Wall and/or leaf height |
Dck, DckS1, DckS2 |
[m] |
Real |
Wall and/or leaf thickness |
BetUebS1, BetUebS2 |
[cm] |
Real |
Concrete cover for leaf 1 + 2 |
VorsSchS1, VorsSchS2 |
[cm] |
Real |
Outer leaf thickness for leaf 1 + 2 |
VsBetGS1, VsBetGS2 |
[ - ] |
String |
Concrete grade for outer leaf |
OberFlS1, OberFlS2 |
[ - ] |
String |
Surface of outer leaves |
GTyp |
[ - ] |
String |
Name of girder type |
GStk |
[ - ] |
Integer |
Number of lattice girders |
AsVorhS1, AsVorhS2 |
[cm2] |
Real |
Existing bar cross-sectional area of longitudinal reinforcement |
AsVorhQS1, AsVorhQS2 |
[cm2] |
Real |
Existing bar cross-sectional area of transverse reinforcement |
BTypS1, BTypS2 |
[ - ] |
String |
Existing reinforcement type for leaf 1 + 2 |
StapelNr |
[ - ] |
Integer |
Stack number |
Attr1 to Attr30 |
[ - ] |
String |
Custom attribute 1 to 30 |
ExpoKl |
[ - ] |
String |
Exposure class text for core layer |
VsExpoS1, VsExpoS2 |
[ - ] |
String |
Exposure class text for (outer) leaves 1+2 |
ZiInfo |
[ - ] |
String |
Bricks used (contents of the Description entry of the brick/tile catalog) |
ZiRast |
[mm] |
Real |
Basic brick dimensions in accordance with design or modification |
ZiLaen |
[mm] |
Real |
Length of brick in accordance with brick/tile catalog |
PA_ProjNr |
[ - ] |
String |
Project attribute: project number |
PA_AuftragNr |
[ - ] |
String |
Project attribute: contract number |
PA_Bauteil |
[ - ] |
String |
Project attribute: component |
PA_Geschoss |
[ - ] |
String |
Project attribute: story |
VsDckS1, VsDckS2 |
[cm] |
Real |
Thickness of facing layer (index 1 indicates the facing layer on the side of the design identifier; index 2 indicates the facing layer on the side opposite the design identifier). |
VsMaterialS1, VsMaterialS2 |
[ - ] |
String |
Material of facing layer (index 1 indicates the facing layer on the side of the design identifier; index 2 indicates the facing layer on the side opposite the design identifier). |
BetGueS1, BetGueS2 |
[ - ] |
String |
Concrete grade of the first and last concrete layers (index 1 indicates the concrete layer on the side of the design identifier; index 2 indicates the concrete layer on the side opposite the design identifier). |
ExpoKlS1, ExpoKlS2 |
[ - ] |
String |
Exposure class text for the wall on the side of the design identifier and on the side opposite the design identifier; |
(C) Allplan GmbH | Privacy policy |