Module(s): Catalogs
Note:
This catalog is only used when the Number of definitions parameter in the Girder distance acc. to panel length configuration is set to 0.
'General' tab
Created on:
Date of creation of the data record.
Last modified:
The most recent modification date.
Name:
User-defined name.
Distribution:
Offsets or patterns of the girders. You can enter a reference letter for the filling mode:
N: (normal): (does not have to be specified) start of placement from one side to the end of the panel.
S: (symmetrical): start of placement from middle outward to both sides.
K: (edge): start of placement first from one side to the middle and then from the other side to the middle.
Examples of girder spacing arrangement
The numbers must be separated by commas.
The first number shows the edge offset or first offset; the other numbers indicate the spacing between axes. Enter * to multiply. Parentheses are also supported.
You have to enter a total for the number of girders such that the maximum panel width can be fully covered. It does not matter if you have too many repetitions, because at the panel end the placement is just terminated.
Valid up to panel width of:
The distribution entered next is to be used up to this panel width.
'->Assignment' tab
Assignment of the individual entries to the appropriate components.
The selected entry is applicable only to the selected components. If no component is selected, the entry is valid for all the components.
(C) Allplan GmbH | Privacy policy |