REMOVALAT

Inhalt

Index

Deactivate the spring of a temporary support point of precast girders created with the task SUPPORTAT and calculate the redistribution of forces (only applicable for precast templates

The reference is given by inputting the reference point and the station of the spring created with the task SUPPORTAT.

The calculation is performed analogously to the task REMOVAL with the calculation tasks DEACTIVATE and LCTRANSFER, thus the redistribution is performed automatically for all automatically created summation load cases.

Arguments

refpt (reference point)

Reference point in the cross section of the precast girder at which the temporary support point was created

at

Station value at which the support point was created

lcsuffix (load case) [optionally]

Suffix for the names of the load cases, which is in each case used to create a load case containing the evaluated forces to be applied

Example: load case = "SW-SUM", lcsuffix = "_removal" -> "SW-SUM_removal”

init [optionally]

Set this option to initialize (set to zero) the results of the considered (deactivated) elements.



Allplan

(C) ALLPLAN GmbH

Privacy policy