Syntax
TRANSFORMATION arg1 arg2
Description
Starting from an axis system, which is determined by the referenced position, various transformations can be applied to position the member.
Arguments
Minimum quantity: 1
arg1
Value |
Meaning |
BEGIN |
Scope will be opened |
END |
Scope will be closed |
arg2 (arg1 = BEGIN)
Value |
Dimension |
Meaning |
ADD |
KEYWORD |
The content of the scope will be added to. |
CLEAR |
KEYWORD |
All transformations are deleted before the scope is imported. |
Scopes
BODY/DOCKING
Examples
TRANSFORMATION BEGIN
INIT ORTHOYG DOCKAT ""
STEP LOCAL DV -1.500 0.000 0.000
TRANSFORMATION END
The own reference position during connection is not specified. This means that the local point {0,0,0} is used. The component is aligned vertically (ORTHOYG) and then shifted by -1.5 in the local direction.
|