Division configuration entry

Configuration Double Wall: Design + Concrete Wall: Design + Brick Wall: Design

'Element dimensions' tab

Minimum element length:

[m] Smaller elements are not created.

Maximum element length:

[m] Larger elements are not created.

Maximum element weight:

[to] Initial value for the maximum element weight. You can also define one (or more) cranes and crane locations in the drawing. In this case the program calculates the maximum weight from the lifting radii, including this weight in division calculations.

rotate from height:

[m] The program internally rotates the element as soon as it reaches this height. Otherwise, the panel would not fit on the pallet.

Maximum length, rotated:

[m] The maximum length for rotated elements is usually the pallet width.

Rounding: (double and concrete walls only)

[m] You can enter a rounding value for the element arrangement.

Joint width:

[m] The size of the joints for panel joints.

Shift value for joint: (double wall only)

[m] Value by which the joints of the two leaves are moved within double walls.

'Openings' tab

Division in opening:

Select this check box if openings are to be divided. Otherwise, the division point is placed next to the opening by the value specified below, where applicable.

Minimum distance to an opening:

[m] Minimum distance of a division point to an opening.