Configuration(s): slab programs: single panel schema, half floor
'Size' tab
Text height for tables [cm]:
Text height for the tables on the right edge of the sheet.
If there is no room on the table
Text reduced down to [cm]:
If this text height limit cannot be met, then the table is printed using normal sized text on a separate sheet. If there is still not enough room on the table, then the entire table is output to a separate sheet.
Maximum table width [cm]:
The dimension for the maximum width of the table.
'Sequence' tab
The table is divided into fields. 0 means that nothing is printed.
Indicate the priority (sequence) you wish the information in the tables. Enter 0 if a category is not to be listed. If you enter the same priority numbers, then there is no optical separation using strikethrough lines.
The categories do not require any further explanation, except:
General:
This is the information enabled in the General tab.
Basic reinforcement list summarized:
Longitudinal or cross bars in an item, per layer, without lengths but with average bar spacing information
e.g. L: 16 d8/15
The reinforcement quantity specified in the table of the single panel schema always represents the longitudinal bars, cross bars and the girders based on the enclosing rectangle of the element! In the case of panels and/or recesses of irregular geometry, individual longitudinal bars, cross bars and girders of the basic reinforcement may be excluded! This is ignored!
Basic reinforcement list detailed (free):
Basic reinforcement list detailed (welded):
Listing of the individual reinforcement items.
'General' tab
Here you define which information appears under "General" in the table.
Include area of panel:
Panel area including bar overlap:
Linear fixtures:
Enter the number of decimal places.
Include panel thickness:
Include panel volume:
Include concrete grade:
Include steel grade:
Include concrete cover:
Include bar cross section:
This is where you set whether and how the bar cross sectional area is output. The reinforcement quantity specified in the table of the single panel schema always represents the longitudinal bars, cross bars and the girders based on the enclosing rectangle of the element! In the case of panels and/or recesses of irregular geometry, individual longitudinal bars, cross bars and girders of the basic reinforcement may be excluded! This is ignored!
'Reinforcement' tab
Include reinforcement type:
Basic reinforcement:
List's sort mode:
The program sorts the basic reinforcement according to the following criteria:
Dia_BS: the program sorts the bars first by diameter and then by bending shape.
Dia_Pos: the program sorts the bars first by diameter and then by position (from left to right).
Reinflay_Pos: the program sorts the bars first by layer 1, 2, etc. and then by position (from left to right).
Reinflay_Length: the program sorts the bars first by layer 1, 2, etc. and then by length (from shortest to longest).
Standard girders:
List's sort mode:
The program sorts the standard girders according to the following criteria:
Typ_Pos: the program sorts the standards girders first by type and then by position (from left to right).
Pos_Length: the girders are sorted first according to position (from left to right) followed by length (from shortest to longest).
Length_Typ: the girders are sorted first according to length (from shortest to longest) followed by type.
Arc secondary bars:
Draw in table:
Yes: arc secondary bars are shown in the table
No: arc secondary bars are not shown in the table
Include length:
Developed length: the arc bars are "unbent" and the total length is shown.
Individual lengths: the lengths of the arc bars are dimensioned individually.
Bending shapes / stirrup shapes:
Number of columns for bending/stirrup shapes:
Enter the number of columns for bending/stirrup shapes you wish to be used in the table.
Width of a drawing as a number of characters:
Enter the number of characters available for the width of a drawing of the bending/stirrup shape.
Height of a drawing as a number of characters:
Enter the number of characters available for the length of a drawing of the bending/stirrup shape.