Contents

Index

Predefined attributes

Tool(s): Define attribute

The following table lists all predefined attributes you can use for precast elements. You can find these attributes in the Precast elements category except User name and Computer, which are in the General category.

Attribute

ID

Description

Absolute_height

204

Height for walls; width for other precast elements

Absolute_length

198

Length of precast element

Absolute_thickness

199

Panel thickness in [m]

Additional text for mark number

1073

Mark number line after design, see configuration -> entry -> labeling

Allfa cost center (abbr. path name)

301

Allfa cost center, code

Area

229

Area [m2]

Bar steel weight

1366

Bar steel weight

Bottom edge of column ... foundation

1935

Bottom edge of column for foundation

Bottom edge of foundation

1933

Bottom edge of foundation

Brick length

1953

Brick length (for brick walls)

Brick name

1952

Brick name (for brick walls)

Chamfer - user entry

1014

Chamfer (text for supplement)

Component name

1893

Name of precast element

Component_supplement

1024

Component (text for supplement)

Computer

403

Computer name

Concr. topping

1876

Concrete topping = slab thickness - panel thickness

Concrete cover at bottom/invisible

1061

 

Concrete cover at top/visible

1062

 

Concrete grade

1063

Concrete grade for slabs; concrete grade of visible leaf for walls

Concrete grade of invisible leaf

1065

For walls only

Concrete grade of invisible outer leaf

1067

For walls only

Concrete grade of visible leaf

1064

For walls only

Concrete grade of visible outer leaf

1066

For walls only

Consecutive number

1932

Consecutive number

Custom attribute

1947

Precast element: custom attributes (with an index 1-n)

Custom attribute 01

1083

Precast element: Custom attribute 01 --> ensuring compatibility! Use 1947!

Custom attribute 02

1084

Precast element: Custom attribute 02 --> ensuring compatibility! Use 1947!

Custom attribute 03

1085

Precast element: Custom attribute 03 --> ensuring compatibility! Use 1947!

Custom attribute 04

1086

Precast element: Custom attribute 04 --> ensuring compatibility! Use 1947!

Custom attribute 05

1087

Precast element: Custom attribute 05 --> ensuring compatibility! Use 1947!

Custom attribute 06

1895

Precast element: Custom attribute 06 --> ensuring compatibility! Use 1947!

Custom attribute 07

1896

Precast element: Custom attribute 07 --> ensuring compatibility! Use 1947!

Custom attribute 08

1897

Precast element: Custom attribute 08 --> ensuring compatibility! Use 1947!

Custom attribute 09

1898

Precast element: Custom attribute 09 --> ensuring compatibility! Use 1947!

Custom attribute 10

1899

Precast element: Custom attribute 10 --> ensuring compatibility! Use 1947!

Custom attribute 11

1900

Precast element: Custom attribute 11 --> ensuring compatibility! Use 1947!

Custom attribute 12

1901

Precast element: Custom attribute 12 --> ensuring compatibility! Use 1947!

Custom attribute 13

1902

Precast element: Custom attribute 13 --> ensuring compatibility! Use 1947!

Custom attribute 14

1903

Precast element: Custom attribute 14 --> ensuring compatibility! Use 1947!

Custom attribute 15

1904

Precast element: Custom attribute 15 --> ensuring compatibility! Use 1947!

Date on which data were transferred to production

1887

Date on which data were transferred to production

Delivery unit status

902

Delivery unit status

Dimensions of precast element [m]

1077

Length x height for walls; length x width for other components

Element name

1021

Mark number line after design, see configuration -> entry -> labeling

Element type

932

The term for slab, roof or balcony in the relevant language

Element_type

1082

Split type, half floor=14021, hollow core element=14022, prestressed hollow core element=14023, concrete slab=14024, brick slab=14026, BubbleDeck=14027, double wall=14031, concrete wall=14032, brick wall=14033

Existing asx at bottom/invisible

1882

Existing as-value at bottom/invisible, longitudinal

Existing asx at top/visible

1881

Existing as-value at top/visible, longitudinal

Existing asy at bottom/invisible

1886

Existing as-value at bottom/invisible, transverse

Existing asy at top/visible

1885

Existing as-value at top/visible, transverse

Exposure class

1031

For slabs: the only exposure class
For concrete walls: the exposure class of the core layer
For double walls: not used

Exposure class, invisible

1033

For double walls: the exposure class of the invisible leaf
For concrete walls: the exposure class of the invisible outer leaf
For slabs: not used

Exposure class, visible

1032

For double walls: the exposure class of the visible leaf
For concrete walls: the exposure class of the visible outer leaf
For slabs: not used

Facing thickness of invisible leaf

1060

For walls only

Facing thickness of visible leaf

1059

For walls only

Factory number

1057

Factory number

FF stirrup cages InstallationSite

1097

installation == on site (1 otherwise 0)

FF stirrup cages InstallationWorks

1096

installation == works (1 otherwise 0)

FF stirrup cages, AvailabilitySpecialReinforcement

1221

FF stirrup cages, AvailabilitySpecialReinforcement (1/0)

FF stirrup cages, AvailabilityStockItems

1220

FF stirrup cages, AvailabilityStockItems (1/0)

FF stirrup cages, code

1045

FF stirrup cages, code (description of the stirrup cage, for example "2495M001/002/BK16")

FF stirrup cages, filter

1044

Filter for FF stirrup cages (Is it an FF stirrup cage? 0/1)

FF stirrup cages, filter for placement

1050

FF stirrup cages, filter for placement, installation = site

FF stirrup cages, ProducerExternal

1224

FF stirrup cages, ProducerExternal (1/0)

FF stirrup cages, ProducerWorks

1225

FF stirrup cages, ProducerWorks (1/0)

FF stirrup cages, reinforcement type 1

1047

Filter for FF stirrup cages - stock items on site

FF stirrup cages, reinforcement type 2

1048

Filter for FF stirrup cages - special reinforcement on site

FF stirrup cages, sorting number

1046

FF stirrup cages, sorting number = stackl# * 1 000 000 000 + stack_height*1 000 000 + element# *1000 + SC#

FF stirrup cages, SupplierExternal

1222

FF stirrup cages, SupplierExternal (1/0)

FF stirrup cages, SupplierWorks

1223

FF stirrup cages, SupplierWorks (1/0)

Fileset name - user entry

1022

Fileset name (text for supplement)

Fileset number - user entry

1025

Fileset number (text for supplement)

Filling object diameter

1951

Diameter of filling object

Filling side SB - user entry

1017

Filling side SB (text for supplement)

Fire resistance classification

935

Fire resistance classification of the precast element

Foundation dimensions [m]

1934

Dimensions of foundation in [m]

Grid dimension

1954

Grid dimension

Height of invisible leaf

1869

Height of invisible leaf

Height of precast element in transport stack

1076

Stacking height

Height of profile

1945

Sleeve foundation, base, height of profile

Height of visible leaf

1868

Height of visible leaf

Index created by

396

Person who is in charge

Invisible reinforcement type

1072

For walls only

Invisible surface

1069

For walls only

Invoice text

1894

Invoice text for precast element

Kind of reinforcement

1415

Filter for reinforcement

Lattice girder steel weight

1367

Steel weight of lattice girders

Layer adjustment BL

1227

Layer adjustment at bottom [m]

Layer adjustment TL

1226

Layer adjustment at top [m]

Layer number of precast element

1981

Layer number of precast element

Ld type

1949

Ld type

Length of bars in element plan

1955

Length of bars in element plan [m]

Local_code_story_name

246

Local code: story name

Mark number of precast element

903

Mark number of precast element

Mark numbers of meshes/bars/fixtures in element plan

1412

Mark numbers of meshes/bars/fixtures in element plan

MarkNumberList

1950

List of mark numbers

Mesh steel weight

1365

Mesh steel weight

Mrk. no. for stack list

1074

Mark number of precast element; if the element is not the first on the stack, a negative sign is used.

Mrk. no. of meshes/bars in element plan

1943

Mark number of meshes/bars in element plan

MrkNo of elements

1455

Mark number of starter bars

MWS reinforcement group filter

1982

Filter for MWS reinforcement group (Is it a group? 0/1)

Name of connection

1450

Name of starter bars

Name of filling object

1941

Precast element: name of filling object

Name of profile

1944

Sleeve foundation, base, name of profile

Net volume of concrete

1219

Net volume of concrete

Number of connections

1451

Number of starter bars

Number of filling objects

1942

Precast element: number of filling objects

Number of meshes/bars/fixtures in element plan

1946

Number of meshes/bars/fixtures in element plan

Number of same foundations

1931

Number of same foundations

Number of same piles

1940

Number of same piles

Object number

307

Object number

Offsets to FF reinforcement component

1054

FF reinforcement component

Page_number

499

Page number in element plan; can be used in V2006 and later

Pallet side - user entry

1015

Pallet side (text for supplement)

Panel type

1088

For hollow core elements and prestressed hollow core elements: the name of the panel type in the catalog; otherwise, the term for slab, roof or balcony in the relevant language

Piece

215

For hollow core elements: the number of elements with the same mark number; otherwise, 1

Pile diameter [m]

1938

Pile diameter [m]

Pile load [kN]

1937

Pile load [kN]

Precast type

1075

The name of the split type as a string; the term for half floor, hollow core element, double wall and so on in the relevant language

Precast ID

1877

A unique ID for each precast element

Precast-IDs (same mark no.)

1929

Precast element: Precast-IDs (same mark no.)

Project name - user entry

1023

Project name (text for supplement)

Reference scale

448

Scale of supplement

Reinforcement type

1070

Reinforcement type for slabs; reinforcement type of visible leaf for walls

Required asx at bottom/invisible

1880

Required as-value at bottom/invisible, longitudinal

Required asx at top/visible

1879

Required as-value at top/visible, longitudinal

Required asy at bottom/invisible

1884

Required as-value at bottom/invisible, transverse

Required asy at top/visible

1883

Required as-value at top/visible, transverse

Secondary reinforcement at connection

1452

Secondary reinforcement for starter bars (diameter, spacing)

Side of precast element layer

1413

Side of precast element layer

Slab thickness

1892

Slab thickness

Smooth filling side - user entry

1016

Smooth filling side (text for supplement)

Sorting ID of stack list

1080

Stack number*100000 + stacking height*1000 + offset of drop-in point from start point of stack in decimeters

Span direction

1930

Precast element: span direction

Stack name

1983

Stack name: text for stack name

Stack number

1079

Stack number

Standard formwork element, bottom step, length

1419

Standard formwork element, bottom step, length

Standard formwork element, bottom step, name

1416

Standard formwork element, bottom step, name

Standard formwork element, normal area, length

1420

Standard formwork element, normal area, length

Standard formwork element, normal area, name

1417

Standard formwork element, normal area, name

Standard formwork element, top step, length

1421

Standard formwork element, top step, length

Standard formwork element, top step, name

1418

Standard formwork element, top step, name

Standard girder type

1872

Standard lattice girder type

Status description

1890

Description of precast element status

Status name

1889

Name of precast element status

Status sequence

1891

Sequence of precast element status

Steel weight

1058

Steel weight in tons

Structural position - user entry

1020

Structural position (text for supplement)

Structure - user entry

1018

Structure (text for supplement)

Symbol

1936

Symbol

Thickness of invisible leaf

1867

Thickness of invisible leaf

Thickness of precast element [cm]

1078

Panel thickness in [cm]

Thickness of visible leaf

1866

Thickness of visible leaf

Top of pile [m]

1939

Top of pile [m]

Total weight

765

Weight in tons

Total weight of stirrup cage

1081

Total weight of stirrup cage

Truck number

1857

Truck number

Type of intersection

1049

Cutting of FF reinforcement

User name

20

User name (login)

Visible reinforcement type

1071

For walls only

Visible surface

1068

For walls only

Volume

223

Volume [m³]

Wall thickness at connection

1454

Wall thickness for starter bars

Washed concrete - user entry

1019

Washed concrete (text for supplement)

Weight

721

Weight in tons

Weight of connection

1453

Weight of starter bars

Weight of meshes/bars in element plan

1948

Weight of meshes/bars in element plan

Width of invisible leaf

1871

Width of invisible leaf

Width of visible leaf

1870

Width of visible leaf



Allplan 2016