Tool(s): Define attribute
The following table lists all predefined attributes you can use for precast elements. You can find these attributes in the Precast elements category except User name and Computer, which are in the General category.
Attribute |
ID |
Description |
Absolute_height |
204 |
Height for walls; width for other precast elements |
Absolute_length |
198 |
Length of precast element |
Absolute_thickness |
199 |
Panel thickness in [m] |
Additional text for mark number |
1073 |
Mark number line after design, see configuration -> entry -> labeling |
Allfa cost center (abbr. path name) |
301 |
Allfa cost center, code |
Area |
229 |
Area [m2] |
Bar steel weight |
1366 |
Bar steel weight |
Bottom edge of column ... foundation |
1935 |
Bottom edge of column for foundation |
Bottom edge of foundation |
1933 |
Bottom edge of foundation |
Brick length |
1953 |
Brick length (for brick walls) |
Brick name |
1952 |
Brick name (for brick walls) |
Chamfer - user entry |
1014 |
Chamfer (text for supplement) |
Component name |
1893 |
Name of precast element |
Component_supplement |
1024 |
Component (text for supplement) |
Computer |
403 |
Computer name |
Concr. topping |
1876 |
Concrete topping = slab thickness - panel thickness |
Concrete cover at bottom/invisible |
1061 |
|
Concrete cover at top/visible |
1062 |
|
Concrete grade |
1063 |
Concrete grade for slabs; concrete grade of visible leaf for walls |
Concrete grade of invisible leaf |
1065 |
For walls only |
Concrete grade of invisible outer leaf |
1067 |
For walls only |
Concrete grade of visible leaf |
1064 |
For walls only |
Concrete grade of visible outer leaf |
1066 |
For walls only |
Consecutive number |
1932 |
Consecutive number |
Custom attribute |
1947 |
Precast element: custom attributes (with an index 1-n) |
Custom attribute 01 |
1083 |
Precast element: Custom attribute 01 --> ensuring compatibility! Use 1947! |
Custom attribute 02 |
1084 |
Precast element: Custom attribute 02 --> ensuring compatibility! Use 1947! |
Custom attribute 03 |
1085 |
Precast element: Custom attribute 03 --> ensuring compatibility! Use 1947! |
Custom attribute 04 |
1086 |
Precast element: Custom attribute 04 --> ensuring compatibility! Use 1947! |
Custom attribute 05 |
1087 |
Precast element: Custom attribute 05 --> ensuring compatibility! Use 1947! |
Custom attribute 06 |
1895 |
Precast element: Custom attribute 06 --> ensuring compatibility! Use 1947! |
Custom attribute 07 |
1896 |
Precast element: Custom attribute 07 --> ensuring compatibility! Use 1947! |
Custom attribute 08 |
1897 |
Precast element: Custom attribute 08 --> ensuring compatibility! Use 1947! |
Custom attribute 09 |
1898 |
Precast element: Custom attribute 09 --> ensuring compatibility! Use 1947! |
Custom attribute 10 |
1899 |
Precast element: Custom attribute 10 --> ensuring compatibility! Use 1947! |
Custom attribute 11 |
1900 |
Precast element: Custom attribute 11 --> ensuring compatibility! Use 1947! |
Custom attribute 12 |
1901 |
Precast element: Custom attribute 12 --> ensuring compatibility! Use 1947! |
Custom attribute 13 |
1902 |
Precast element: Custom attribute 13 --> ensuring compatibility! Use 1947! |
Custom attribute 14 |
1903 |
Precast element: Custom attribute 14 --> ensuring compatibility! Use 1947! |
Custom attribute 15 |
1904 |
Precast element: Custom attribute 15 --> ensuring compatibility! Use 1947! |
Date on which data were transferred to production |
1887 |
Date on which data were transferred to production |
Delivery unit status |
902 |
Delivery unit status |
Dimensions of precast element [m] |
1077 |
Length x height for walls; length x width for other components |
Element name |
1021 |
Mark number line after design, see configuration -> entry -> labeling |
Element type |
932 |
The term for slab, roof or balcony in the relevant language |
Element_type |
1082 |
Split type, half floor=14021, hollow core element=14022, prestressed hollow core element=14023, concrete slab=14024, brick slab=14026, BubbleDeck=14027, double wall=14031, concrete wall=14032, brick wall=14033 |
Existing asx at bottom/invisible |
1882 |
Existing as-value at bottom/invisible, longitudinal |
Existing asx at top/visible |
1881 |
Existing as-value at top/visible, longitudinal |
Existing asy at bottom/invisible |
1886 |
Existing as-value at bottom/invisible, transverse |
Existing asy at top/visible |
1885 |
Existing as-value at top/visible, transverse |
Exposure class |
1031 |
For slabs: the only exposure class |
Exposure class, invisible |
1033 |
For double walls: the exposure class of the invisible leaf |
Exposure class, visible |
1032 |
For double walls: the exposure class of the visible leaf |
Facing thickness of invisible leaf |
1060 |
For walls only |
Facing thickness of visible leaf |
1059 |
For walls only |
Factory number |
1057 |
Factory number |
FF stirrup cages InstallationSite |
1097 |
installation == on site (1 otherwise 0) |
FF stirrup cages InstallationWorks |
1096 |
installation == works (1 otherwise 0) |
FF stirrup cages, AvailabilitySpecialReinforcement |
1221 |
FF stirrup cages, AvailabilitySpecialReinforcement (1/0) |
FF stirrup cages, AvailabilityStockItems |
1220 |
FF stirrup cages, AvailabilityStockItems (1/0) |
FF stirrup cages, code |
1045 |
FF stirrup cages, code (description of the stirrup cage, for example "2495M001/002/BK16") |
FF stirrup cages, filter |
1044 |
Filter for FF stirrup cages (Is it an FF stirrup cage? 0/1) |
FF stirrup cages, filter for placement |
1050 |
FF stirrup cages, filter for placement, installation = site |
FF stirrup cages, ProducerExternal |
1224 |
FF stirrup cages, ProducerExternal (1/0) |
FF stirrup cages, ProducerWorks |
1225 |
FF stirrup cages, ProducerWorks (1/0) |
FF stirrup cages, reinforcement type 1 |
1047 |
Filter for FF stirrup cages - stock items on site |
FF stirrup cages, reinforcement type 2 |
1048 |
Filter for FF stirrup cages - special reinforcement on site |
FF stirrup cages, sorting number |
1046 |
FF stirrup cages, sorting number = stackl# * 1 000 000 000 + stack_height*1 000 000 + element# *1000 + SC# |
FF stirrup cages, SupplierExternal |
1222 |
FF stirrup cages, SupplierExternal (1/0) |
FF stirrup cages, SupplierWorks |
1223 |
FF stirrup cages, SupplierWorks (1/0) |
Fileset name - user entry |
1022 |
Fileset name (text for supplement) |
Fileset number - user entry |
1025 |
Fileset number (text for supplement) |
Filling object diameter |
1951 |
Diameter of filling object |
Filling side SB - user entry |
1017 |
Filling side SB (text for supplement) |
Fire resistance classification |
935 |
Fire resistance classification of the precast element |
Foundation dimensions [m] |
1934 |
Dimensions of foundation in [m] |
Grid dimension |
1954 |
Grid dimension |
Height of invisible leaf |
1869 |
Height of invisible leaf |
Height of precast element in transport stack |
1076 |
Stacking height |
Height of profile |
1945 |
Sleeve foundation, base, height of profile |
Height of visible leaf |
1868 |
Height of visible leaf |
Index created by |
396 |
Person who is in charge |
Invisible reinforcement type |
1072 |
For walls only |
Invisible surface |
1069 |
For walls only |
Invoice text |
1894 |
Invoice text for precast element |
Kind of reinforcement |
1415 |
Filter for reinforcement |
Lattice girder steel weight |
1367 |
Steel weight of lattice girders |
Layer adjustment BL |
1227 |
Layer adjustment at bottom [m] |
Layer adjustment TL |
1226 |
Layer adjustment at top [m] |
Layer number of precast element |
1981 |
Layer number of precast element |
Ld type |
1949 |
Ld type |
Length of bars in element plan |
1955 |
Length of bars in element plan [m] |
Local_code_story_name |
246 |
Local code: story name |
Mark number of precast element |
903 |
Mark number of precast element |
Mark numbers of meshes/bars/fixtures in element plan |
1412 |
Mark numbers of meshes/bars/fixtures in element plan |
MarkNumberList |
1950 |
List of mark numbers |
Mesh steel weight |
1365 |
Mesh steel weight |
Mrk. no. for stack list |
1074 |
Mark number of precast element; if the element is not the first on the stack, a negative sign is used. |
Mrk. no. of meshes/bars in element plan |
1943 |
Mark number of meshes/bars in element plan |
MrkNo of elements |
1455 |
Mark number of starter bars |
MWS reinforcement group filter |
1982 |
Filter for MWS reinforcement group (Is it a group? 0/1) |
Name of connection |
1450 |
Name of starter bars |
Name of filling object |
1941 |
Precast element: name of filling object |
Name of profile |
1944 |
Sleeve foundation, base, name of profile |
Net volume of concrete |
1219 |
Net volume of concrete |
Number of connections |
1451 |
Number of starter bars |
Number of filling objects |
1942 |
Precast element: number of filling objects |
Number of meshes/bars/fixtures in element plan |
1946 |
Number of meshes/bars/fixtures in element plan |
Number of same foundations |
1931 |
Number of same foundations |
Number of same piles |
1940 |
Number of same piles |
Object number |
307 |
Object number |
Offsets to FF reinforcement component |
1054 |
FF reinforcement component |
Page_number |
499 |
Page number in element plan; can be used in V2006 and later |
Pallet side - user entry |
1015 |
Pallet side (text for supplement) |
Panel type |
1088 |
For hollow core elements and prestressed hollow core elements: the name of the panel type in the catalog; otherwise, the term for slab, roof or balcony in the relevant language |
Piece |
215 |
For hollow core elements: the number of elements with the same mark number; otherwise, 1 |
Pile diameter [m] |
1938 |
Pile diameter [m] |
Pile load [kN] |
1937 |
Pile load [kN] |
Precast type |
1075 |
The name of the split type as a string; the term for half floor, hollow core element, double wall and so on in the relevant language |
Precast ID |
1877 |
A unique ID for each precast element |
Precast-IDs (same mark no.) |
1929 |
Precast element: Precast-IDs (same mark no.) |
Project name - user entry |
1023 |
Project name (text for supplement) |
Reference scale |
448 |
Scale of supplement |
Reinforcement type |
1070 |
Reinforcement type for slabs; reinforcement type of visible leaf for walls |
Required asx at bottom/invisible |
1880 |
Required as-value at bottom/invisible, longitudinal |
Required asx at top/visible |
1879 |
Required as-value at top/visible, longitudinal |
Required asy at bottom/invisible |
1884 |
Required as-value at bottom/invisible, transverse |
Required asy at top/visible |
1883 |
Required as-value at top/visible, transverse |
Secondary reinforcement at connection |
1452 |
Secondary reinforcement for starter bars (diameter, spacing) |
Side of precast element layer |
1413 |
Side of precast element layer |
Slab thickness |
1892 |
Slab thickness |
Smooth filling side - user entry |
1016 |
Smooth filling side (text for supplement) |
Sorting ID of stack list |
1080 |
Stack number*100000 + stacking height*1000 + offset of drop-in point from start point of stack in decimeters |
Span direction |
1930 |
Precast element: span direction |
Stack name |
1983 |
Stack name: text for stack name |
Stack number |
1079 |
Stack number |
Standard formwork element, bottom step, length |
1419 |
Standard formwork element, bottom step, length |
Standard formwork element, bottom step, name |
1416 |
Standard formwork element, bottom step, name |
Standard formwork element, normal area, length |
1420 |
Standard formwork element, normal area, length |
Standard formwork element, normal area, name |
1417 |
Standard formwork element, normal area, name |
Standard formwork element, top step, length |
1421 |
Standard formwork element, top step, length |
Standard formwork element, top step, name |
1418 |
Standard formwork element, top step, name |
Standard girder type |
1872 |
Standard lattice girder type |
Status description |
1890 |
Description of precast element status |
Status name |
1889 |
Name of precast element status |
Status sequence |
1891 |
Sequence of precast element status |
Steel weight |
1058 |
Steel weight in tons |
Structural position - user entry |
1020 |
Structural position (text for supplement) |
Structure - user entry |
1018 |
Structure (text for supplement) |
Symbol |
1936 |
Symbol |
Thickness of invisible leaf |
1867 |
Thickness of invisible leaf |
Thickness of precast element [cm] |
1078 |
Panel thickness in [cm] |
Thickness of visible leaf |
1866 |
Thickness of visible leaf |
Top of pile [m] |
1939 |
Top of pile [m] |
Total weight |
765 |
Weight in tons |
Total weight of stirrup cage |
1081 |
Total weight of stirrup cage |
Truck number |
1857 |
Truck number |
Type of intersection |
1049 |
Cutting of FF reinforcement |
User name |
20 |
User name (login) |
Visible reinforcement type |
1071 |
For walls only |
Visible surface |
1068 |
For walls only |
Volume |
223 |
Volume [m³] |
Wall thickness at connection |
1454 |
Wall thickness for starter bars |
Washed concrete - user entry |
1019 |
Washed concrete (text for supplement) |
Weight |
721 |
Weight in tons |
Weight of connection |
1453 |
Weight of starter bars |
Weight of meshes/bars in element plan |
1948 |
Weight of meshes/bars in element plan |
Width of invisible leaf |
1871 |
Width of invisible leaf |
Width of visible leaf |
1870 |
Width of visible leaf |
(C) Allplan GmbH | Privacy policy |