You can specify the maximum height and width of the legend in [mm]. This defined area is reserved for the legend when the element plan is created. If the legend requires less space, the remaining space is empty.
If, for example, you add reinforcement later, the legend is enlarged up to the maximum size. If the legend exceeds the space reserved, the legend is resized (font size is reduced) and, if necessary, divided into several columns.
Note that you cannot use the same legends as in the placing drawing as the element plan uses the local mark numbers for reinforcing bars and meshes. If necessary, modify the existing legends. Instead of the Number of meshes/bars, Weight of meshes/bars and Mark number of meshes/bars attributes of the Engineering area, use the Number of meshes/bars in element plan, Weight of meshes/bars in element plan and Mark number of meshes/bars in element plan attributes of the Precast concrete elements area. Do not use the Sum up option when you create the legend!
Tip: You can use the Legend layout element to create a reinforcement schedule consisting of a single sheet. Define a separate sheet and specify the maximum height and width by entering the size of the sheet.