'Table' tab
General
Name:
Any name; this name is displayed in the tree structure of the layout catalog.
Contents:
You can specify whether the Entire component or Individual layers of the component are displayed for multi-tier walls (double wall, wall panels, thermal wall).
Contents of "individual layers"
This area is only available when you have selected Individual layers in the General area.
Layer 1 (visible) / Layer 2 / Layer 3 / Layer 4 / Layer 5 / Layer 6:
Select the layers that are included in the table. Proceed as you would when making settings for the views.
Contents of "page"
Visible side / Center / Invisible side
Select the contents of the table. Proceed as you would when making settings for the views.
Options
Maximum table length/width:
Enter the maximum length and width of the table in [mm]. This defined area is reserved for the table and taken into account when the scale is determined automatically. If the table requires less space, the remaining space is empty.
The table's min-max-box is displayed in construction line format in the element plan. When you specify a fixed scale, you can immediately check whether elements extend into the table.
The table is only created within the defined area. Data is added to the table up to the predefined table length. If there is enough space for a second column, a second column is added. Otherwise, the font size of the first column is reduced so that a second column can be created. However, the percentage specified for the Reduce text to parameter is the upper limit for reducing the font size.
Text attributes:
Enter or select attributes for the text in the table. The height and width of the text are entered in [mm] and the font angle in [degrees].
Reduce text to:
Enter the percentage up to which the text in the table is reduced so that all the data fits in the first and, if necessary, second column of the table within the predefined area. If this limit is reached and data is still missing, a warning is displayed at the end of the table.
Unit of length
Select [cm] or [mm] for the unit.
Sequence in tables
Specify whether the elements of the visible side or invisible side are listed first. For double walls, the sequence in the table is usually equivalent to the arrangement of the views on the sheet.
'Table I' tab
You can use the Use option and Sequence in table number, which are provided in each area, to specify whether and where the individual elements of the precast element are written in the table - the higher the number, the lower the priority.
You can define additional parameters for the following areas.
General
Include area of panel:
Includes the panel area in the table. Special customer-specific billing computation modes are not taken into account.
Include concrete grade, panel thickness, panel volume:
Select the items that you want to include in the table. If you select the panel volume, the weight is included, too.
Balls:
You can choose from the Number of balls, Cage length per meter or Number of balls and cage length.
The cage length per meter is calculated as follows: (number of filling objects * diameter of filling objects in [mm]) / 0.9 ) / 1000
Basic reinforcement, general
Include steel grade, concrete cover, reinforcement type:
Enable the items that you want to be included in the table.
Include bar cross section:
You can choose between as required or as present.
The reinforcement quantity specified in the table of the element plan always represents the longitudinal bars, cross bars and the girders based on the enclosing rectangle of the element! In the case of panels and/or recesses of irregular geometry, individual longitudinal bars, cross bars and lattice girders of the basic reinforcement may be excluded! This is ignored!
Bars / Meshes summarized:
When this option is not selected, the bars or meshes are not summarized in the table.
Include length of bar reinforcement:
When this option is not selected, the bar length is not included.
Basic reinforcement, details
Listing of the individual reinforcement items.
List's sort mode:
If the reinforcement list is enabled, you can sort it in various ways:
Diameter_BS: bar diameter has the highest priority followed by bending shape.
Diameter_Mrk: bar diameter has the highest priority followed by the coordinates in the panel (from left to right)
Layer_Mrk: the reinforcement is sorted first according to its layer (from the reinforcement type) followed by the coordinates in the panel (from left to right).
Layer_Length: the reinforcement is sorted first according to its layer (from the reinforcement type) followed by its length (shortest to longest).
Standard girders
List's sort mode:
If standard girders are enabled, you can sort the list in various ways:
Length_Type: the girders are sorted first according to length (shortest to longest) followed by type.
Mrk_Length: the girders are sorted first according to position (from left to right) followed by length (shortest to longest).
Type_Mrk: girder type has the highest priority followed by the coordinates in the panel (from left to right)
Secondary bars
Arc bars with graphics:
Specify whether arc bars are to be included or not.
Width / height of a drawing as a number of characters:
Enter the number of characters available for the width/height of a drawing of a bending shape.
Bent-up meshes
Show stirrup shapes:
Specify whether the stirrup shape is to be displayed beside the bent-up mesh or not.
Width / height of a drawing as a number of characters:
Enter the number of characters available for the width/height of a drawing of a stirrup shape.
Include segment lengths:
When this option is selected, the segment lengths of the stirrup shapes are included.
'Table II' tab
You can use the Use option and Sequence in table number, which are provided in each area, to specify whether and where the individual elements of the precast element are written in the table - the higher the number, the lower the priority.
You can define additional parameters for the following areas.
Stirrup cages
Show stirrup shapes:
Specify whether the stirrup shape is to be displayed beside the stirrup cage or not.
Width / height of a drawing as a number of characters:
Enter the number of characters available for the width/height of a drawing of a stirrup shape.
Include segment lengths:
When this option is selected, the segment lengths of the stirrup shapes are included.
Bending shapes
Number of columns for bending shapes:
Enter the number of columns for bending shapes you want to use in the table.
Width / height of a drawing as a number of characters:
Enter the number of characters available for the width/height of a drawing of a bending shape.
Include segment lengths:
When this option is selected, the segment lengths of the bending shapes are included.
Stirrup shapes
Number of columns for bending shapes:
Enter the number of columns for stirrup shapes you want to use in the table.
Width / height of a drawing as a number of characters:
Enter the number of characters available for the width/height of a drawing of a stirrup shape.
Include segment lengths:
When this option is selected, the segment lengths of the stirrup shapes are included.
Fixtures
You can specify the use and number for each individual fixture type.
Text:
Specify whether fixtures are to be labeled as specified in the fixture catalog or whether the plan text, list text or reference text is used.
Special formwork
Pattern no.:
Number of Allplan pattern line which is used to identify element edges with special formwork. The total length of the special formwork including a legend can be listed in the table.
Attributes:
Enter the Height and Width of the pattern line in [mm]. If the value for the height and/or width is 0, the program uses a default value of 3 mm.