Reinforcement type catalog, wall panel

Module(s): Catalogs

'General' tab

Created on:

Date of creation of the data record.

Last modified:

The most recent modification date.

Name:

User-defined name, which is displayed in the element parameters when designing and in the list box of the Reinforcement configuration.

Description:

User-defined name that can be included in labels for element plans or lists/schedules (not yet implemented).

Search criterion:

By entering a search criterion for the element parameters in the design tool, you can filter the reinforcement types. This enables you e.g., to use just reinforcement types complying with a search criterion "M".

'Reinforcement data' tab

as total: [cm² /m]

Cross sectional area for all reinforcement. The program searches the reinforcement types for this value if you reinforce according to "as". If you do not reinforce according to as-Value but select the reinforcement type as per the drawing, then any entry in this field can be suppressed.

Mesh:

Selection box for the mesh catalog.
For the meshes of the inner layer of reinforcement, the diagonal is automatically turned before it is created.

as long/transv.: [cm² /m]

Cross sectional area of longitudinal or transverse reinforcement.

Longitudinal bars:

Selection box for the diameter catalog. You can specify up to 2 longitudinal bar diameters (layers) for the reinforcement in an element.

Cross bars:

Selection box for the diameter catalog. You can specify up to 2 cross bar diameters (layers) for the reinforcement in an element. The first layer is mostly used for spacers (see NC generator configuration), the second to place the required amount of cross bar reinforcement.

Distribution:

Offsets or pattern of the bars. This is mainly entered with edge offset and distribution parameters (e.g., 50,200*60 = 50mm edge offset, then 200mm up to 60 times). You can enter a reference letter for the filling mode (pattern): the formula fills a data entry field, which has a limit of 200 entries. You can also have a maximum of 200 bars per layer. If the formula exceeds 200 entries, then the placement does not fill the panel. (For example: 30.50*199 places cross bars up to max. 9.98m (199*5 +3cm edge offset). A 10.5m long panel would be too long).

N: (normal): (does not have to be specified) start of placement from one side to the end of the panel.

S: (symmetrical): start of placement from middle outward to both sides.

K: (edge): start of placement first from one side to the middle and then from the other side to the middle.

Examples of bar distribution

Use commas to separate the values.

The first number shows the edge offset or first offset; the other numbers indicate the spacing between axes. Enter * to multiply. You can also use parentheses.

You have to enter a total for the number of bars such that the maximum panel width or length can be fully covered. It does not matter if you have too many repetitions, because at the panel end the placement is just terminated.

'->Fact.' tab

Assignment of the individual entries to the relevant factories.

The selected entry is applicable to the selected factories. If no factory is selected, the entry is valid for all the factories.