Priority rating at T-connections

Multi-layer walls

To obtain correct results with T-connections, assign the same priority rating to the construction layers that are to intersect.

This applies both to connections obtained as you draw and connections that arise as a result of the
Join Linear Components and
Join Linear Component with Line tools.

Legend:

A

Exterior wall’s priority ratings:
Layer 1 = 500
Layer 2 = 400
Layer 3 = 300
Layer 4 = 200

B

Exterior side

C

Priority ratings of interior wall:
Layer 1 = 200
Layer 2 = 300
Layer 3 = 200

Figure: priority rating at T-connections



Allplan 2016
(C) Allplan GmbH Privacy policy