Syntax
SCOMP arg1 arg2 arg3 arg4 arg5 arg6 arg7 arg8 arg9 arg10 arg11 arg12
Description
Knowing which longitudinal beams together form a panel is important for the verification programs. The definition of the panel is similar to the definition of the composite. As the panel definition made here is not part of the activated global static system then there is no need to enter a node position and element numbers.
Arguments
Minimum number: 3
arg1
Value |
unit |
Meaning |
iunit |
INT |
Number of the panel unit in the cross-section |
arg2
Value |
unit |
Meaning |
COMP |
KEYWORD |
The numbers of the bars that form the plate then follow. |
arg3 - arg10 (arg2 = COMP)
Value |
unit |
Meaning |
kunit |
TEXT |
Numbers of up to 8 individual bars that define the composite |
Scopes
CSECTION/CUNITS
Examples
PLATE 21 COMP 1 4 7 10 13
The panel 21 consists of individual bars 1, 4, 7, 10 and 13.
|
(C) ALLPLAN GmbH |