TCL Command SMEMBER

Inhalt

Index

Syntax

SMEMBER arg1

Description

The member is created by cutting out a structural unit from a station-wise defined reference member. This command is valid only for EXTRACT type bodies.

Arguments

Minimum quantity: 1

arg1

Value

Dimension

Meaning

mname

TEXT

Name of the reference member

Scopes

BODY

Examples

BODY "Body1" EXTRACT BEGIN

TEXT "Body"

SMEMBER "Girder 1"

SBEGIN 12.000000 ROTATE 0.00000 0.00000

SEND 37.000000 ROTATE 30.00000 0.00000

UNIT "1"

BODY END

The body "Body1" is created by cutting out the structural unit "1" from the member "Girder 1" from station 12.000000 to station 37.000000. The cut at the end is made at the angle of 30°.