Syntax
COMBROW arg1 arg2 ....
Description
The combination of input results are typed. All input results are superimposed from right to left according to the selected superposition rule and factors. Optionally, the calculated line-by-line results can be considered again in a group of envelopes. The use of the line in the groups is entered after the character '|'.
Arguments
Minimum quantity: 2
arg1
Value |
Dimension |
Meaning |
rname |
TEXT |
Name of envelope row |
arg2
Value |
Dimension |
Meaning |
rtype |
ENUM |
General envelope type from list {"CHAR", "FREQ", "PERM", "QPERM", "ULS", "FATIGUE", "ACCIDENT"} |
rtype_en |
ENUM |
Euronorm-specific type from list {"EN_FAT-BNC", "EN_FAT-CQ", "DIN_RARE"} |
rtype_aashto |
ENUM |
AASHTO-specific type from list {"AA_STR-I", "AA_STR-II"; "AA_STR-III", "AA_STR-IV", "AA_STR-V", "AA_EXT-I", "AA_EXT-II", "AA_SER-I", "AA_SER-II", "AA_SER-III", "AA_SER-IV", "AA_FAT-I", "AA_FAT-II"} |
arg3, arg4, … (The factors for the unfavorable and favorable superposition follow alternately according to the selected columns HEADCOL and LOADCOL)
Value |
Dimension |
Meaning |
funfav |
ENUM |
Factor for unfavorable superposition or '-' if the superposition is not to be executed. |
ffavor |
ENUM |
Factor for favorable superposition or '-' if the superposition is not to be executed. |
'-' |
KEYWORD |
Superposition is not to be executed. |
arg-pipe (closing the input of factors)
Value |
Dimension |
Meaning |
'|' |
KEYWORD |
The character closes the input of factors. The character is optionally followed by the assignment to the groups (GROUPCOL) |
arg-pipe+1, arg-pipe+2, ....
Value |
Dimension |
Meaning |
'-' |
KEYWORD |
The row is not considered to be superimposed into the group. |
OR |
KEYWORD |
The line is superimposed into the group using the OR rule (see TCL Command SUP). |
Scopes
COMBTABLE
Examples
# 1:1 1:2 2:1 3:1 4:1 5:1 5:2 5:3 5:4 5:5 5:6 5:7 | G1
# UNFAV FAV UNFAV FAV UNFAV FAV UNFAV FAV UNFAV FAV UNFAV FAV UNFAV FAV UNFAV FAV UNFAV FAV UNFAV FAV UNFAV FAV UNFAV FAV |
COMBROW "C1" CHAR 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 - 1.000 1.000 1.000 1.000 - - - - 0.600 - 0.600 - - - | -
COMBROW "C2" FREQ 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 - 0.750 0.750 0.400 0.400 - - - - - - 0.500 - - - | -
COMBROW "C3" QPERM 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 - - - - - - - - - - - 0.500 - - - | -
COMBROW "C4" ULS 1.350 1.000 1.350 1.000 1.000 1.000 1.000 1.000 1.200 - 1.350 1.350 1.350 1.350 - - - - 0.900 - 0.900 - - - | OR
COMBROW "C5" ULS 1.350 1.000 1.350 1.000 1.000 1.000 1.000 1.000 1.200 - 1.013 1.013 0.540 0.540 1.350 1.350 1.350 1.350 0.900 - 0.900 - - - | OR
COMBROW "C6" ACCIDENT 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 - - - - - - - - - - - 0.500 - 1.000 1.000 | -
The superposition scheme contains 6 lines of different types. The columns were created in advance. This is where the appropriate factors are set. An additional group ”G1” is used, into which the lines "C4” and "C5” are superimposed.
|
(C) ALLPLAN GmbH |