TCL Command COMBROW

Inhalt

Index

Syntax

COMBROW arg1 arg2 ....

Description

The combination of input results are typed. All input results are superimposed from right to left according to the selected superposition rule and factors. Optionally, the calculated line-by-line results can be considered again in a group of envelopes. The use of the line in the groups is entered after the character '|'.

Arguments

Minimum quantity: 2

arg1

Value

Dimension

Meaning

rname

TEXT

Name of envelope row

arg2

Value

Dimension

Meaning

rtype

ENUM

General envelope type from list {"CHAR", "FREQ", "PERM", "QPERM", "ULS", "FATIGUE", "ACCIDENT"}

rtype_en

ENUM

Euronorm-specific type from list {"EN_FAT-BNC", "EN_FAT-CQ", "DIN_RARE"}

rtype_aashto

ENUM

AASHTO-specific type from list {"AA_STR-I", "AA_STR-II"; "AA_STR-III", "AA_STR-IV", "AA_STR-V", "AA_EXT-I", "AA_EXT-II", "AA_SER-I", "AA_SER-II", "AA_SER-III", "AA_SER-IV", "AA_FAT-I", "AA_FAT-II"}

arg3, arg4, … (The factors for the unfavorable and favorable superposition follow alternately according to the selected columns HEADCOL and LOADCOL)

Value

Dimension

Meaning

funfav

ENUM

Factor for unfavorable superposition or '-' if the superposition is not to be executed.

ffavor

ENUM

Factor for favorable superposition or '-' if the superposition is not to be executed.

'-'

KEYWORD

Superposition is not to be executed.

arg-pipe (closing the input of factors)

Value

Dimension

Meaning

'|'

KEYWORD

The character closes the input of factors. The character is optionally followed by the assignment to the groups (GROUPCOL)

arg-pipe+1, arg-pipe+2, ....

Value

Dimension

Meaning

'-'

KEYWORD

The row is not considered to be superimposed into the group.

OR

KEYWORD

The line is superimposed into the group using the OR rule (see TCL Command SUP).

Scopes

COMBTABLE

Examples

# 1:1 1:2 2:1 3:1 4:1 5:1 5:2 5:3 5:4 5:5 5:6 5:7 | G1

# UNFAV FAV UNFAV FAV UNFAV FAV UNFAV FAV UNFAV FAV UNFAV FAV UNFAV FAV UNFAV FAV UNFAV FAV UNFAV FAV UNFAV FAV UNFAV FAV |

COMBROW "C1" CHAR 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 - 1.000 1.000 1.000 1.000 - - - - 0.600 - 0.600 - - - | -

COMBROW "C2" FREQ 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 - 0.750 0.750 0.400 0.400 - - - - - - 0.500 - - - | -

COMBROW "C3" QPERM 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 - - - - - - - - - - - 0.500 - - - | -

COMBROW "C4" ULS 1.350 1.000 1.350 1.000 1.000 1.000 1.000 1.000 1.200 - 1.350 1.350 1.350 1.350 - - - - 0.900 - 0.900 - - - | OR

COMBROW "C5" ULS 1.350 1.000 1.350 1.000 1.000 1.000 1.000 1.000 1.200 - 1.013 1.013 0.540 0.540 1.350 1.350 1.350 1.350 0.900 - 0.900 - - - | OR

COMBROW "C6" ACCIDENT 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 - - - - - - - - - - - 0.500 - 1.000 1.000 | -

The superposition scheme contains 6 lines of different types. The columns were created in advance. This is where the appropriate factors are set. An additional group ”G1” is used, into which the lines "C4” and "C5” are superimposed.



Allplan

(C) ALLPLAN GmbH

Privacy policy