Syntax
POINT arg1 arg2 arg3 arg4 arg5 arg6 arg7
Description
Input of a reference position and optional positioning of an "Allplan Smart Placement".
Arguments
Minimum number: 3
arg1
Value |
unit |
Meaning |
pname |
TEXT |
Point name |
arg2
Value |
unit |
Meaning |
LSECT |
KEYWORD |
Reference point defined by a point of intersection of two parametric lines |
POINT |
KEYWORD |
Reference point defined by a parametric point |
arg3 - arg4 (arg2 = LSECT)
Value |
unit |
Meaning |
line1[:i] |
TEXT |
Name of the 1st reference line of the point of intersection; the optional suffix ":1" or ":2" determines the number of the point of intersection if an arc is part of the intersection. As there can be up to two points of intersection, one of the two must be determined. This can be on either the first or second clipping line. |
line2[:i] |
TEXT |
Name of the 2nd reference line of the point of intersection; the optional suffix ":1" or ":2" determines the number of the point of intersection if an arc is part of the intersection. As there can be up to two points of intersection, one of the two must be determined. This can be on either the first or second clipping line. |
arg5 (arg2 = LSECT)
Value |
unit |
Meaning |
APLACE |
KEYWORD |
This is followed by positioning an Allplan Smart Placement with the following arguments. |
arg6 (arg2 = LSECT)
Value |
unit |
Meaning |
0 |
INT |
Smart Placement is deactivated at each station where the cross-section was assigned |
1 |
INT |
Smart Placement is selected at each station where the cross-section was assigned |
apvar |
TEXT |
Activation of the smart placement by a variable (type NONE) whose value at the station is 0 or 1 |
arg7 (arg2 = LSECT)
Value |
unit |
Meaning |
- |
- |
If no entry is made, the direction of the placement is the local Y direction. |
YG |
KEYWORD |
The direction of placement is the global Y direction. |
arg3 (arg2 = POINT)
Value |
unit |
Meaning |
pname |
TEXT |
Name of the parametric point |
arg4 (arg2 = POINT)
Value |
unit |
Meaning |
APLACE |
KEYWORD |
This is followed by positioning an Allplan Smart Placement with the following arguments. |
arg5 (arg2 = POINT)
Value |
unit |
Meaning |
0 |
INT |
Smart Placement is deactivated at each station where the cross-section was assigned |
1 |
INT |
Smart Placement is selected at each station where the cross-section was assigned |
apvar |
TEXT |
Activation of the smart placement by a variable (type NONE) whose value at the station is 0 or 1 |
arg6 (arg2 = POINT)
Value |
unit |
Meaning |
- |
- |
If no entry is made, the direction of the placement is the local Y direction. |
YG |
KEYWORD |
The direction of placement is the global Y direction. |
Scopes
CGREF
Examples
POINT "Bearing_L" LSECT "L48" "L49" APLACE "Bearings"
Definition of the position of bearing "Bearing_L" at the point of intersection of the lines "L48" and "L49". The point also determines the position of the "Allplan Smart Placement" of the same name, whereby its activation along the component is controlled by the "Bearings” variable.
|
(C) ALLPLAN GmbH |