TCL Command POINT

Inhalt

Index

Syntax

POINT arg1 arg2 arg3 arg4 arg5 arg6 arg7

Description

Input of a reference position and optional positioning of an "Allplan Smart Placement".

Arguments

Minimum number: 3

arg1

Value

unit

Meaning

pname

TEXT

Point name

arg2

Value

unit

Meaning

LSECT

KEYWORD

Reference point defined by a point of intersection of two parametric lines

POINT

KEYWORD

Reference point defined by a parametric point

arg3 - arg4 (arg2 = LSECT)

Value

unit

Meaning

line1[:i]

TEXT

Name of the 1st reference line of the point of intersection; the optional suffix ":1" or ":2" determines the number of the point of intersection if an arc is part of the intersection. As there can be up to two points of intersection, one of the two must be determined. This can be on either the first or second clipping line.

line2[:i]

TEXT

Name of the 2nd reference line of the point of intersection; the optional suffix ":1" or ":2" determines the number of the point of intersection if an arc is part of the intersection. As there can be up to two points of intersection, one of the two must be determined. This can be on either the first or second clipping line.

arg5 (arg2 = LSECT)

Value

unit

Meaning

APLACE

KEYWORD

This is followed by positioning an Allplan Smart Placement with the following arguments.

arg6 (arg2 = LSECT)

Value

unit

Meaning

0

INT

Smart Placement is deactivated at each station where the cross-section was assigned

1

INT

Smart Placement is selected at each station where the cross-section was assigned

apvar

TEXT

Activation of the smart placement by a variable (type NONE) whose value at the station is 0 or 1

arg7 (arg2 = LSECT)

Value

unit

Meaning

-

-

If no entry is made, the direction of the placement is the local Y direction.

YG

KEYWORD

The direction of placement is the global Y direction.

arg3 (arg2 = POINT)

Value

unit

Meaning

pname

TEXT

Name of the parametric point

arg4 (arg2 = POINT)

Value

unit

Meaning

APLACE

KEYWORD

This is followed by positioning an Allplan Smart Placement with the following arguments.

arg5 (arg2 = POINT)

Value

unit

Meaning

0

INT

Smart Placement is deactivated at each station where the cross-section was assigned

1

INT

Smart Placement is selected at each station where the cross-section was assigned

apvar

TEXT

Activation of the smart placement by a variable (type NONE) whose value at the station is 0 or 1

arg6 (arg2 = POINT)

Value

unit

Meaning

-

-

If no entry is made, the direction of the placement is the local Y direction.

YG

KEYWORD

The direction of placement is the global Y direction.

Scopes

CGREF

Examples

POINT "Bearing_L" LSECT "L48" "L49" APLACE "Bearings"

Definition of the position of bearing "Bearing_L" at the point of intersection of the lines "L48" and "L49". The point also determines the position of the "Allplan Smart Placement" of the same name, whereby its activation along the component is controlled by the "Bearings” variable.



Allplan

(C) ALLPLAN GmbH

Privacy policy