TCL Command EXPCLASS

Inhalt

Index

Syntax

EXPCLASS arg1 arg2 arg3 ....

Description

The classification is made according to the selected standard. Multiple classes can be specified at the same time.

Arguments

Minimum quantity: 1

arg1

Value

Dimension

Meaning

EN

KEYWORD

Euronorm

AASHTO_LRFD

KEYWORD

AASHTO LRFD

arg2, arg3, … (arg1 = EN)

Value

Dimension

Meaning

X0

KEYWORD

No risk of corrosion

XC1

KEYWORD

Corrosion due to carbonic acid formation, dry or permanently wet

XC2

KEYWORD

Corrosion due to carbonic acid formation, moist - rarely dry

XC3

KEYWORD

Corrosion due to carbonic acid formation, moderate humidity

XC4

KEYWORD

Corrosion due to carbonic acid formation, cyclically wet and dry

XD1

KEYWORD

Corrosion due to chloride, moderate humidity

XD2

KEYWORD

Corrosion due to chloride, moist - rarely dry

XD3

KEYWORD

Corrosion due to chloride, cyclically wet and dry

XS1

KEYWORD

Corrosion due to chloride from seawater, exposed to salt in the air but not in direct contact with seawater

XS2

KEYWORD

Corrosion by chloride from seawater, constantly submerged

XS3

KEYWORD

Corrosion due to chloride from seawater, tides, splash water and splash zones.

XF1

KEYWORD

Freeze/thaw attack, moderate water saturation without deicing agent

XF2

KEYWORD

Freeze/thaw attack, moderate water saturation with deicing agent

XF3

KEYWORD

Freeze/thaw attack, high water saturation without deicing agent

XF4

KEYWORD

Freeze/thaw attack, high water saturation with deicing agents or seawater.

XA1

KEYWORD

Chemical attack, slightly aggressive chemical environment according to EN 206-1, Table 2

XA2

KEYWORD

Chemical attack, moderate aggressive chemical environment according to EN 206-1, Table 2

XA3

KEYWORD

Chemical attack, heighly aggressive chemical environment according to EN 206-1, Table 2

arg2, arg3, … (arg1 = AASHTO_LRFD)

Value

Dimension

Meaning

C0

KEYWORD

No risk

C1

KEYWORD

Concrete exposed to moisture but not to an external source of chloride

C2

KEYWORD

Concrete exposed to moisture and an external source of chlorides from deicing chemicals, salt, brackish water, seawater, or splash water from these sources

CF

KEYWORD

Definition of the attack strength by the user specified factor gamma_e

Scopes

EXPOSUREZONE

Examples

EXPCLASS EN XC3 XD1 XF3

Attack zone "Zone1" defined by boundary line "Boundary1" . The classification is made according to Euronorm.