Generate a report for the checks in the Strength Limit Sate and Service Limit State for the elements assigned by assemblies
Note: To perform this task you need to perform a respective check with the task CODECHECK in advance and create a respective result name.
The report file is saved in MS-Word format in a respective subfolder of the project directory.
Arguments
Result name (resname)
Result name for which the report should be generated; it refers to the name as defined within the task CODECHECK, under which the results are stored.
Flexure (flexure) / Fatigue (fatigue) / Brittle failure (brittle) / Shear (shear) / Torsion (torsion) / Interaction (interact) / Stress limitation (stresslim) / Crack control (crack) /Detailing (detailing)
Selection for which results the report should be created
For details see CODECHECK.
Extended scope (extended)
Option to enhance the report with an output of the load history of the application (summation) of the permanent loads over all points in time of the construction phase based on the used envelope (acting section forces, stress/strain state and respective cross section resistance) (not available for the options shear, torsion and detailing)
|
(C) ALLPLAN GmbH |
Privacy policy |