The commands for reinforcement are splitted in one command for the form and one command for the placement. The form command is like a directive. The form is valid until it is replaced by another form. The valid form can be placed in different placements.
The layer of the reinforcement objects can be set with the script directive LAYER. All other common properties as there are pen, line and linetype are fixed to the default values
To define the form and place the bar use script commands like:
REINF_STIRRUP_RC ... , ...
REINF_PLACE_L … , ...
Currently available placementtyps are: REINF_PLACE, REINF_PLACE_L, REINF_PLACE_C.
The naming rules for the forms: “REINF_” + “BAR / STIRRUP” + Form + specialization
For the form these abbreviations are valid:
L=linear
R=rectangular
Q=quadrangular
P=polygonal
C=circular
F=free
For the specialization these abbreviations are valid:
C=closed
O=open
2=planar
D=diamond
S=S-shaped
L=L-shaped
PL=polyline
CB=corbel
CN=corner
T=Torsion
SB=Starter Bar
HL=horizontal loop
SP=spacer
The abbreviations for form is mandatory, the one for specialization is optional.
Examples:
REINF_STIRRUP_RC ..... rectangular (R) , closed (C) Stirrup
REINF_BAR_L ..... liniar (L) bar
REINF_STIRRUP_QO ..... quadrangular (Q), open (O) Stirrup
REINF_BAR_PL ..... polygonal (P) , L-shaped (L) bar
REINF_BAR_L