Domaine d'activité Precast Wall
Owing to the wide range of parameters available for the factory configurations, catalogs and the parameters currently set by the user during element design or modification and owing to the current geometry of the element (outline or recesses), the program may not create all bars or lattice girders of the basic reinforcement and thus may not reinforce all parts of the element (e.g. corners with acute angles, narrow webs between recesses or between recesses and the edges). The program does not check that all the bars and lattice girders are actually created.
That is why you need to spend some time thinking about how to handle non-rectangular element outlines and recesses. These considerations can be described as "engineering thinking". This is exactly the reason why the Precast Elements role requires some experience. In particular, do not create production data without checking the reinforcement beforehand.
To design the elements for a precast wall
(C) ALLPLAN GmbH |