Manual mark number for bars/meshes in the element plan
When editing elements of precast elements within the element plan, it was possible that several full schemas were present in the element plan for a local mark number of the bars (or meshes).
The prerequisite for this, was that
- in the
configurations for the relevant element type under Design (wall, slab) or element creation (structural precast elements) or in the element type catalog of the
catalogs under Element creation definition (precast elements) on the General registry tab of the title Element plan for Local mark number and the setting Manual was selected, - that at least two identical bars (or meshes) in the layout (placing drawing) have different global mark numbers, and
- that the bars (or meshes) rearranged later in the element plan initially have different mark numbers and each have a full schema.
If these bars (or meshes) are rearranged in the element plan, then the full schemas remain, each with an identical mark number. This behavior has now been rectified. Now all full schemas are deleted (except for one) and a warning message is shown beforehand, via which you can decide if you want to cancel the rearrangement and therefore also deletion.
The corresponding warning message now appears during
- repositioning in the layout when the element plan is closed if at least two identical bars (or meshes) have different global mark numbers in the element plan each have a full schema with different local mark numbers. By repositioning the global mark numbers in the layout, at least one full schema must be deleted in the element plan.
- Repositioning the local mark number of the bar (or meshes) when the element plan is open if at least two identical bars (or meshes) are present that have different global mark numbers in the layout and different local mark numbers in the element plan. By repositioning the local mark numbers in the element plan, all other full schemas in the element plan are deleted except for one.